top of page

TEM sample preparation

Sample2_edited.jpg
Sample1_edited.jpg

User fees:

  • Chemical fixation + Epon embedding:

  • Pre-embedding live cell CLEM:

  • Cryo-fixation for morphology:

  • Cryo-fixation for immuno EM/CLEM:

  • Tokuyasu sectioning (iEM/CLEM):

  • Progressive lowering temperature:

  • Plunge freezing:

  • Negative staining:

​€40,-/sample (>10 = €20,- per sample)

€60,-/sample (>10 = €30,- per sample)

€60,-/sample (>10 = €30,- per sample)

€60,-/sample (>10 = €30,- per sample)

€50,-/sample (>10 = €30,- per sample)

€50,-/sample (>10 = €30,- per sample)

€10,-/grid (In case not internal TEM use)

Included with use TEM

Leica EM ICE High Pressure Freezer

​Contact person: Rinse de Boer

rinse.de.boer@rug.nl

​

Cryo-fixation of cell suspensions, adhering cells or tissue

​

  • Fixation in 3mm or 6mm carriers (suspensions)

  • Fixation in copper tubes for frozen hydrated sectioning and cryo electron microscopy

  • Fixations of cells on  saphire discs for combining live-cell fluorescence microscopy and electron microscopy

Leica AFS2 + FSP liquid handler

​Contact person: Rinse de Boer

rinse.de.boer@rug.nl

​

Automated freeze substitution of cryo fixed specimens facilitating analysis of ultra structure at room temperature close to native state

​

  • Freeze substitution in mixture of OsO4 and uranyl in acetone and embedding in epon (morphology)

  • Freeze substitution in uranyl acetate in acetone and embedding in lowicryl (iEM/CLEM)

Sample processing hoods

​Contact person: Rinse de Boer

rinse.de.boer@rug.nl

​

Leica UC6

​Contact person: Rinse de Boer

rinse.de.boer@rug.nl

​

Room temperture sectioning:

​

  • Ultrathin sectioning for standard 2D TEM analysis

  • Semi thin sectioning for electron tomography

  • Serial sectioning for array tomography

​

Glass knives and diamond knives are availble depending of practical experience

Reichert-Jung Utracut E + FC4

​Contact person: Rinse de Boer

rinse.de.boer@rug.nl​

​

Cryo-ultramicrotomy:

​

  • Tokuyasu cryo-sectioning for immuno electron microscopy

  • Tokuyasu cryo-sectioning for Correlative Light and Electron Microscopy (CLEM)

  • Diatome Static Line III: Preventing charging of knive and sections

​

Glass knives and diamond knives are availble depending of practical experience

Vitrobot 

​

Contact person: Marc Stuart

Plunge freezing in liquid ethane:

​

  • Cryo-fixation of small particles <500nm imaged directly with cryo electron microscopy​

bottom of page